Equipped with metal fiber filter elements that withstand temperatures up to 450℃, the solution achieves a PM removal efficiency of no less than 95%, ensuring stable performance even under frequent start-stop operation.
Adopts differential pressure linked pulse jet cleaning, enabling automatic ash removal and discharge. For low-load operating scenarios, an optional heating regeneration function is available, delivering effortless and efficient operation.
Features a triple-protection system, including a high-temperature bypass valve, overpressure protection, and pressure monitoring, effectively preventing engine power loss.
Integrated with a PLC and touchscreen control system, it enables seamless docking with the test bench control system. Full process data traceability is realized; it supports communication with the test bench system and records data related to cleaning operations and alarm events.